HP Insight Control for Linux 6.0 User Guide

23.26 Troubleshooting virtual machine installation and setup problems
Corrective actionCause/Symptom
Perform the appropriate actions:
For Xen , use the uname command as follows to verify
that the VM host is running a Xen kernel:
# uname -r
2.6.18-92.e15xen
The text string xen should be embedded in the output.
NOTE: If the server is not running the appropriate
kernel, you need:
to repeat the installation of the VM host,
to add any missing Xen components, or
configure the host to boot from the Xen kernel.
For more information, see Section 12.1 (page 139).
Ensure that the rocommunity string in the /etc/
snmp/snmpd.conf file is public
# grep rocommunity /etc/snmp/snmpd.conf
rocommunity public 127.0.0.1
rocommunity public 192.0.2.55
Verify that the sign-in credentials are correct.
Run OptionsIdentify Systems... to identify the VM
host.
Run the following command and look for entries from
Virt_*.
# cimprovider -l
Ensure that the libvirt-cim and libcmpiutil
packages are installed:
For the RHEL 5.2 and SLES 10 operating systems, these
packages are installed by running the
ConfigureConfigure or Repair Agents... task on
the VM host, selecting to install HP Insight Control
virtual machine management.
For all other supported operating systems, install these
packages from the RHEL or SLES distribution media.
HP SIM did not properly identify the virtual host
Perform the appropriate actions:
Verify that the virtual host is properly identified. (See
HP SIM did not properly identify the virtual host in
this table.)
Run the following command and look for entries from
both cmpiOSBase* and Virt_*.
# cimprovider -l
Ensure that the sblim-cmpi-base, libvirt-cim,
and libcmpiutil packages are installed.
For the RHEL 5.2 and SLES 10 operating systems, these
packages are installed by running the
ConfigureConfigure or Repair Agents... task on
the VM host, selecting to install HP Insight Control
virtual machine management.
For all other supported operating systems, install these
packages from the RHEL or SLES distribution media.
Verify the network name on the system page for the
CMS. If it is not a fully qualified domain name, stop
and restart SIM.
Could not register the Virtual Machine Host with HP
Insight Control virtual machine management
23.26 Troubleshooting virtual machine installation and setup problems 255