HP Insight Control for Linux 7.0 Installation Guide

Do you want to proceed? (y/n) [y] y
NOTE: Default responses to all questions are enclosed in square brackets ([ ]). Press Enter
to accept a default response.
5. Indicate whether or not you have read and accept the license agreement. If you have not read
the agreement, enter n to display and read the agreement now.
Have you read the license agreement? (y/n) [n]
Do you accept this license agreement? (y/n) [n]
The installation process does not start until you read and accept the license agreement.
6. Watch the screen during the first part of the installation process, which verifies that all required
RPMs are installed on the CMS.
If all required RPMs are installed, proceed to step 7.
If the installation process detects that RPM dependencies are missing, messages similar
to the following appear:
An RPM dependency is missing: {RPM_name}
Before you can continue, you must install all missing RPM dependencies on the CMS.
After you install all RPM dependencies, return to step 3 to start the installation process
again.
7. Respond to the following configuration questions. If you need help with your answers, enter
a question mark (?) or see Table 11 (page 38).
Gathering configuration data...
For more information about how to answer a configuration question,
enter a question mark(?).
Press enter to continue. Enter
Would you like to use an existing Oracle database as the HP SIM database? (y/n) [n]
1
Device IP
------- -----------------------
eth0 192.0.2.10
Enter which network device to use for the CMS management interface: [eth0]
2
Enter TCP Port for the Insight Control for Linux repository web server: [60000]
3
MANAGEMENT PROCESSOR CREDENTIALS
IMPORTANT - The user name and password selected here will be added to any management
processor that is discovered through the bare metal discovery process.
If that user name already exists, the existing password will be overwritten by the
password specified here.
Enter ? for complete details and configuration alternatives.
Enter the default management processor user name: [Administrator]
Enter the default management processor password:
4
Re-enter to verify:
Enter the IC-Linux collection name: [icelx]
5
Enter the HP SIM CMS user name: [root]
6
Enter the HP SIM CMS password:
Re-enter to verify:
Do you want the CMS to automatically export /hptc_cluster to the management
hub nodes? (y/n) [n]
7
Do you want the CMS to be a DHCP server? (y/n) [n]
8
1
Table 11 (page 38) lists the information you are required to supply for a pre-existing
Oracle database. If you answer yes to this question, the HP Insight Control for Linux
installation process collects all of the information pertaining to the location of and
credentials for the Oracle database and ensures that Systems Insight Manager is
installed appropriately for use with the Oracle database.
5.4 Running the Insight Control for Linux install.sh installation script 43