HP Insight Control Performance Management 7.3 User Guide

Smart Array Controller Inventory
Controller Configuration
Controller identification, including controller model and PCI slot (if applicable)
Supported and negotiated PCI protocols (bus speed)
Controller cache configuration
Number of hard disks attached to the controller
Number of SCSI ports currently in use on the controller
Number of arrays on the controller
Number of array logical drives defined on the controller
Windows/Linux Physical Disks—Lists the physical disk drives and identifies each drive SCSI
ID, drive letter, and associated Smart Array controller.
SCSI adapter
The following information is provided for a SCSI adapter.
SCSI Adapter Status
Transfers/Sec—Number of requests between the server and this SCSI adapter each second
MBytes/Sec—Average number of megabytes transferred (read and written) between the server
and this SCSI adapter each second
Millisec/Transfer—Average time for each request to complete
Queue Length—Average number of concurrent requests between the server and this SCSI
adapter, including transfers currently being serviced and transfers waiting for service, regardless
of where the request is waiting (drive or adapter)
SCSI adapter performance is based on the performance of the SCSI disks attached to the adapter
and the SCSI buses that attach the disks to the adapter.
SCSI Adapter Inventory
Supported and negotiated PCI protocol (bus speed) used by the SCSI adapter.
Number of SCSI drives configured on the adapter.
Number of SCSI ports used.
Windows/Linux Physical Disks—Lists the physical disk drives and identifies each drive SCSI
ID, drive letter, and associated SCSI adapter.
Drive array
The following information is provided for a drive array.
Drive Array Status
Reads/Sec—Number of reads from each drive in the drive array each second
Writes/Sec—Number of writes to each drive in the drive array each second
Read MBytes/Sec—Nverage number of megabytes read from each drive in the drive array
each second
Write MBytes/Sec—Average number of megabytes written to each drive in the drive array
each second
Millisec/Read—Average time for each read to complete
SCSI adapter 55