HP Insight Management 7.2 Update 2 Support Matrix

Table 61 Requirements and capabilities for HP ProLiant BL servers (continued)
Intelligent
Power
Discovery
Data
Center
Power
Control
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum
system BIOS
version
Minimum
iLO or OA
firmware
version
Server
model
1.30 or
later
2
1/29/09iLO 2
version
ProLiant
BL685 G5
1.30 or
later
2
A17
5/7/2009
iLO 2
version
ProLiant
BL685c G6
1.79 or
later
NoneiLO 3
version
ProLiant
BL685c G7
1.05 and(AMD
OA version
3.10
Opteron
6100)
NoneiLO 3
version
ProLiant
BL685c G7
1.05 and(AMD
OA version
3.10
Opteron
6200)
NoneiLO 3
version
ProLiant
BL685c G7
1.05 and(AMD
OA version
3.10
Opteron
6300)
1
For Enclosure Dynamic Power Capping, iLO 2 version 1.70 or later. Otherwise, iLO 2 version 2 1.30 or later.
For Enclosure Dynamic Power Capping, OA 2.30 or later. Otherwise, OA 1.30 or later.
2
When you are implementing power capping for HP BladeSystem, HP recommends that you use Enclosure Dynamic Power
Capping set through the Onboard Administrator or Insight Control power management user interface. To use Enclosure
Dynamic Power Capping, you must upgrade your iLO 2 firmware to version 1.70 or later and iLO 3 to version 1.0 or
later. HP recommends that you update your system ROM to version 10/1/2008 or later for iLO 2, and May 2010 or
later for iLO 3 for G7 servers. For some older BL460c servers, the iLO 2 firmware might not be able to automatically
update the Dynamic Power Capping hardware circuit. In these instances, the Onboard Administrator will compensate
for the absence of the internal hardware circuit and continue to guarantee circuit protection.
3
This server model does not support HP Dynamic Power Savings mode.
Table 62 Requirements and capabilities for HP ProLiant workstation blades
Intelligent
Power
Discovery
Data
Center
Power
Control
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum
system BIOS
version
Minimum
iLO or OA
firmware
version
Server
model
1
8/5/2008iLO 2
version
ProLiant
xw2x220c
1.60 or
later.
OA version
2.30 or
later.
2
7/31/2007iLO 2
version
ProLiant
xw460c
1.30 or
later
74 Hardware requirements and supported capabilities for Insight Control power management