HP BladeSystem Management Pack (v 1.x) for Microsoft System Center User Guide

The Tree pane also displays the status of the monitor service and the enclosure monitoring
status.
Detail pane (middle)
The content of this pane changes according to the node selected from the Tree pane.
Actions pane (right)
The content of this pane, which can be collapsed and expanded, changes according to the
node selected from the Tree pane.
Status line
Located at the bottom of the Enclosure Monitor Manager, this field displays the following
messages:
Ready
There is no problem with the monitor service.
Failed with Monitor Service
The monitor manager failed to communicate with the monitor service
Wizard and data autorefresh are disabled.
To re-enable wizards and auto refresh, see “Refreshing monitor data (page 16).
Connecting/Refreshing
An auto or manual refresh is in progress.
Updating
A wizard was launched, and the enclosure configuration is changing.
Launching the Enclosure Monitor Manager
The monitor manager can be launched in any of the following ways:
From the actions pane of the Group diagram and Monitor Service views
From the Start menu
From a command line
When launching from a command line, the IP address of the target monitor service can be
passed to the monitor manager. For example, the following command uses the local host IP
address for a monitor service that is running locally:
HPBladeSystemEnclosureMonitorManager.exe 127.0.0.1
Multiple monitor managers can run at the same time and simultaneously connect to the same
monitor service. Only one user at a time can launch a wizard to change the enclosure configuration
to a particular monitor service.
Connecting to the Enclosure Monitor Service
If the monitor manager is launched without having a command line argument or Connect button
specifying the monitor service, the Connect screen is displayed.
The Connect button is available from the File menu, or from the Actions pane and menu when you
select the HP BladeSystem Enclosure Monitor Manager from the Tree pane.
1. Select or enter the Monitor Service Hostname, and then click Connect.
The Monitor Service Hostname field enables you to select a previously chosen monitor service
connection.