Table 1 Hardware configuration tasks
Underlying STK utilityDescriptionTask
setbootorder.exeSets the system boot order. Setting PXE first in the boot order is
required.
Boot Order
conrep.exe or
hprcu.exe
Sets the system BIOS configuration.BIOS
hpacuscripting.exeSets the Smart Array RAID configuration.Smart Array
hponcfg.exeSets the iLO 2 or later configuration.iLO
The tasks are designed to set/write a configuration, not get/read/capture a configuration.
The Smart Array configuration task is designed to configure only internal controllers and disks,
not network-based storage.
NOTE: The Set BIOS Configuration task supports all ProLiant generations. If you use a custom
conrep or hprcu input file, the task sequence will become ProLiant generation specific. For
example, if you specify a custom conrep input file, the task sequence will fail on ProLiant Gen8 or
later target servers.
There is a custom task editor for each task. For example:
The file / parameters combo box allows selecting one of the provided filenames/parameters or
typing in a custom filename/parameters. The pre-supplied files are located in .\OSD\Lib\
Packages\HP\ProLiant\HWConfig. The files provided are listed in Table 2 (page 14).
Table 2 Pre-supplied files
DescriptionFile
Does not set anythingconrep-d.xml
Does not set anythinghprcu-d.xml
Creates a default configurationacu-rd.ini
Creates one array with RAID 0acu-r0.ini
Creates one array with RAID 1 (requires two drives)acu-r1.ini
Creates one array with RAID 5 (requires three or more drives)acu-r5.ini
Does not set anythinghponcfg-d.xml
14 Reference