Backing up and restoring HP Insight Management 7.3 Central Management Server (Windows)

Technical white paper | HP Insight Management 7.3
Figure 7: Using the VCEM VC Domains tab to view the current status of the VC Domain
3. After phase 2 execution is complete, you have the opportunity to repeat this phase. However, before you do, you must
reissue the request to remove the VC Domain from the restore VCEM database. You can reissue the
Remove From VC
Domain Group
request by selecting
Tools
Integrated Consoles
Virtual Connect Enterprise Manager (VCEM)
in
Systems Insight Manager. Click the
VC Domains
tab to remove the selected VC Domain from the VCDG.
After the VC Domain is removed from the VCEM database, you can return to mxsync and respond y to the prompt
“Would you like to repeat this synchronization phase? (Y/N.)”
Important:
Do not proceed to the
Logical server Synchronization
section until all added and removed VC Domains have been processed
successfully. Recommendations made during the
Logical server
Synchronization
section are based on the assumption that
the VCEM database is up-to-date. If this is not the case, then the recommended actions may be incorrect.
4. After you have successfully completed the VCEM phases, you can proceed to the
Logical server Synchronization
section. During this section, any logical server definition or storage pool entry in the restored Matrix OE database that is
associated with an EXTERNAL MAC or WWN address is deleted from the database.
5. During the
HP IO Synchronization
section (phase 2), you have the opportunity to update the restored infrastructure
orchestration database to delete infrastructure orchestration services that are no longer assigned to blades in VC
Missing External
Manager Lock
77