HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 111
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureFanLocation
cpqRackCommonEnclosureFanSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack
[cpqRackName] has been removed.”
NT Event ID: 1154 (Hex)0x44350482 (cpqsvmsg.dll)
Log Severity: Information (1)
Event Title: Rack Enclosure Fan Inserted
Log Message: The enclosure fan has been inserted.
SNMP Trap: cpqRackEnclosureFanInserted - 22012 in CPQRACK.MIB
Symptom: The enclosure fan has been inserted.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureFanLocation
cpqRackCommonEnclosureFanSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack
[cpqRackName] has been inserted.”
NT Event ID: 1155 (Hex)0xc4350483 (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Rack Power Supply Failed
Log Message: This trap indicates that a power supply has failed.
SNMP Trap: cpqRackPowerSupplyFailed - 22013 in CPQRACK.MIB
Symptom: The power supply status has been set to failed. This trap indicates that a power supply has
failed.
User Action: Replace the power supply as soon as possible.
Supporting SNMP Trap Data: