HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 115
Event Title: Rack Power Subsystem Input Voltage Problem
Log Message: The rack power supply detected an input line voltage problem.
SNMP Trap: cpqRackPowerSubsystemLineVoltageProblem - 22019 in CPQRACK.MIB
Symptom: The rack power supply detected an input line voltage problem.
User Action: Check the power input for the power supply or replace any failed power supplies as
soon as possible.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackPowerSupplyEnclosureName
cpqRackPowerSupplyPosition
cpqRackPowerSupplyFWRev
cpqRackPowerSupplyInputLineStatus
cpqRackPowerSupplySparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The rack power supply detected an input line voltage problem in
power supply [cpqRackPowerSupplyPosition], enclosure [cpqRackPowerSupplyEnclosureName], rack
[cpqRackName].”
NT Event ID: 1162 (Hex)0x8435048a (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Overload
Log Message: The rack power subsystem overload condition.
SNMP Trap: cpqRackPowerSubsystemOverloadCondition - 22020 in CPQRACK.MIB
Symptom: The rack power subsystem overload condition.
User Action: Replace any failed power supplies as soon as possible to return the system to a
redundant state.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackPowerEnclosureName
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The power subsystem in enclosure
[cpqRackPowerEnclosureName] in rack [cpqRackName] is in an overload condition.”