HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Storage agents 46
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsFanModuleLocation
cpqSsFanModuleStatus
cpqSsFanModuleSerialNumber
cpqSsFanModuleBoardRevision
Supporting SNMP Trap Description: “Storage system fan status changed to [cpqSsFanModuleStatus].”
NT Event ID: 1153 (Hex)0x84350481 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Power Supply Status Change.
Log Message: Storage system “%4” power supply in bay %5 has a new status of %6.
SNMP Trap: cpqSsEx2PowerSupplyStatusChange - 8021 in CPQSTSYS.MIB
Symptom: Storage system power supply status change. The agent has detected a change in the power
supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status.
User Action: If the power supply status is failed, restore power or replace the failed power supply.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsPowerSupplyBay
cpqSsPowerSupplyStatus
cpqSsPowerSupplySerialNumber
cpqSsPowerSupplyBoardRevision
cpqSsPowerSupplyFirmwareRevision
Supporting SNMP Trap Description: “Storage system power supply status changed to
[cpqSsPowerSupplyStatus].”
NT Event ID: 1154 (Hex)0x84350482 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Power Supply UPS Status Change.
Log Message: The UPS attached to storage system “%4” power supply bay %5 has a new status of
%7.
SNMP Trap: cpqSsExPowerSupplyUpsStatusChange - 8018 in CPQSTSYS.MIB
Symptom: Storage system power supply UPS status change. The agent has detected a change status
of a UPS attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus
indicates the current status.
User Action: If the UPS status is powerFailed(4) or batteryLow(5), restore power to the UPS.
Supporting SNMP Trap Data:
sysName