HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide
Storage agents 57
SNMP Trap: cpqIdeAtaDiskStatusChange - 14004 in CPQIDE.MIB
Symptom: ATA Disk Status Change. This trap indicates that the agent has detected a change in the
status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status.
User Action: If the physical drive status is smartError(3) or failed(4), replace the drive.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqIdeAtaDiskControllerIndex
• cpqIdeAtaDiskIndex
• cpqIdeAtaDiskModel
• cpqIdeAtaDiskFwRev
• cpqIdeAtaDiskSerialNumber
• cpqIdeAtaDiskStatus
• cpqIdeAtaDiskChannel
• cpqIdeAtaDiskNumber
Supporting SNMP Trap Description: “Status is now [cpqIdeAtaDiskStatus] for the ATA disk.”
NT Event ID: 1187 (Hex)0x843504a3 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: ATA RAID Logical Drive Status Change.
Log Message: ATA RAID logical drive number %6 on the “%5” in slot %4 has a new status of %2.
SNMP Trap: cpqIdeLogicalDriveStatusChange - 14005 in CPQIDE.MIB
Symptom: IDE Logical Drive Status Change. This trap indicates that the agent has detected a change
in the status of an IDE logical drive. The variable cpqIdeLogicalDriveStatus indicates the current
logical drive status.
User Action: If the logical drive status is failed(5), examine the array for failed drives that need
replacement.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqIdeControllerModel
• cpqIdeControllerSlot
• cpqIdeLogicalDriveControllerIndex
• cpqIdeLogicalDriveIndex
• cpqIdeLogicalDriveStatus
Supporting SNMP Trap Description: “Status is now [cpqIdeLogicalDriveStatus] for the IDE logical
drive.”
NT Event ID: 1188 (Hex)0x843504a4 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.