HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide
Server agents 89
• cpqHoTrapFlags
• cpqHeResMem2BoardSlotNum
• cpqHeResMem2BoardCpuNum
• cpqHeResMem2BoardRiserNum
Supporting SNMP Trap Description: “Memory Board or Cartridge Inserted into Slot
[cpqHeResMem2BoardSlotNum], Cpu[cpqHeResMem2BoardCpuNum],
Riser[cpqHeResMem2BoardRiserNum].”
NT Event ID: 1039 (Hex) 0x8435040FL (cpqsvmsg.dll)
Log Severity: Warning (3)
Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The
LockStep recovery engine has been activated. For instruction on replacing the faulty memory, see the
server documentation.
SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6068 in CPQHLTH.MIB
Symptom: Advanced Memory Protection LockStep Engine Memory Engaged. The Advanced Memory
Protection subsystem has detected a memory fault. The LockStep engine has been activated.
User Action: Replace the faulty memory.
Supporting SNMP Trap Data:
• sysName,
• cpqHoTrapFlags
Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the
LockStep memory.”
NT Event ID: 1040 (Hex) 0xC43504A0L (cpqsvmsg.dll)
Log Severity: Warning (3)
Log Message: The fault tolerant power supply AC power loss for the specified chassis and bay
location.
SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6069 in CPQHLTH.MIB
Symptom: The fault tolerant power supply AC power loss for the specified chassis and bay location.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqHeFltTolPowerSupplyChassis
• cpqHeFltTolPowerSupplyBay
• cpqHeFltTolPowerSupplyStatus
• cpqHeFltTolPowerSupplyModel
• cpqHeFltTolPowerSupplySerialNumber
• cpqHeFltTolPowerSupplyAutoRev
• cpqHeFltTolPowerSupplyFirmwareRev
• cpqHeFltTolPowerSupplySparePartNum
• cpqSiServerSystemId
Supporting SNMP Trap Description: “The Power Supply AC power loss in [sysName], Bay
[cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model