HP Insight Management Agent 8.40 Microsoft Windows Event ID and SNKP Traps Reference Guide

Server agents 97
Log Message: A computer cover has been removed since last system start up. Be sure the system
cover is installed properly. This situation may result in improper cooling of the system due to air flow
changes caused by the missing cover.
SNMP Trap: cpqSiHoodRemoved - 2001 in CPQSINFO.MIB
Symptom: The access panel is removed. The access panel status has been set to removed. The access
panel is not installed properly. This situation may result in improper cooling of the system due to air
flow changes caused by the missing access panel.
User Action: Replace the access panel and be sure that it is installed properly. Verify that the system is
working properly.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Hood is removed from unit.”
NT Event ID: 1116 (Hex)0x8435045c (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Remote Insight Board has detected that the mouse cable is disconnected.
SNMP Trap: cpqSm2MouseCableDisconnected - 9009 in CPQSM2.MIB
Symptom: Mouse Cable Disconnected. The Remote Insight mouse cable has been disconnected.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Remote Insight mouse cable disconnected.”
NT Event ID: 1117 (Hex)0x8435045d (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Remote Insight Board has detected that the external power cable is disconnected.
SNMP Trap: cpqSm2ExternalPowerCableDisconnected - 9010 in CPQSM2.MIB
Symptom: External Power Cable Disconnected. The Remote Insight external power cable has been
disconnected.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “Remote Insight external power cable disconnected.”
NT Event ID: 1118 (Hex)0x4435045e (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: The Fault Tolerant Power Supply Sub-system has been returned to the OK state.
SNMP Trap: cpqHe4FltTolPowerSupplyOk - 6048 in CPQHLTH.MIB
Symptom: The fault tolerant power supply condition has been set back to the OK state for the
specified chassis and bay location.