HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are
found, the adapter, Hub, or Switch may need replacement.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqNicIfPhysAdapterSlot
• cpqNicIfPhysAdapterPort
• cpqSiServerSystemId
• cpqNicIfPhysAdapterStatus
• cpqSePciSlotBoardName
• cpqNicIfPhysAdapterPartNumber
• ipAdEntAddr
• cpqNicIfLogMapIPV6Address
Supporting SNMP Trap Description: “Connectivity lost for adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort].”
NT Event ID: 1292 (Hex)0x4435050C (cpqnimsg.dll)
Log Severity: Information (1)
Log Message: Redundancy has been increased by the NIC in slot %1, port %2. Number of functional
NICs in the team: %3.
SNMP Trap: cpqNic3RedundancyIncreased - 18013 in CPQNIC.MIB
Symptom: This trap is sent any time a previously failed physical adapter in a connected logical
adapter group returns to the OK condition. This trap is not sent when a logical adapter group has
connectivity restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead.
This can be caused by replacing of a faulty cable or connecting a cable that was disconnected.
User Action: None required.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqNicIfPhysAdapterSlot
• cpqNicIfPhysAdapterPort
• cpqSiServerSystemId
• cpqNicIfPhysAdapterStatus
• cpqSePciSlotBoardName
• cpqNicIfPhysAdapterPartNumber
• ipAdEntAddr
• cpqNicIfLogMapIPV6Address
• cpqNicIfLogMapAdapterOKCount
Supporting SNMP Trap Description: “Redundancy increased by adapter in slot
[cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort].”
NT Event ID: 1293 (Hex)0xc435050D (cpqnimsg.dll)
Log Severity: Error (3)
Event Identifiers 300-1293 127