HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide

Log Message: Redundancy has been reduced by the NIC in slot %1, port %2. Number of functional
NICs in the team: %3.
SNMP Trap: cpqNic3RedundancyReduced - 18014 in CPQNIC.MIB
Symptom: This trap is sent any time a physical adapter in a logical adapter group changes to the
Failed condition, but at least one physical adapter remains in the OK condition. This can be caused
by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal
adapter, Hub, or Switch failures can also cause this condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are
found, the adapter, Hub, or Switch may need replacement.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
cpqNicIfLogMapAdapterOKCount
Supporting SNMP Trap Description: “Redundancy decreased by adapter in slot
[cpqNicIfPhysAdapterSlot], port [cpqNicIfPhysAdapterPort].
128 NIC agents