Event identifier: cpqhsmsg.dll - 2315 (Hex)0x8435090b (Service Event)
Log Severity: Warning (2)
Log Message: The Threshold Agent did not respond to a request. The data contains the error code.
Event identifier: cpqhsmsg.dll - 2316 (Hex)0x8435090c (Service Event)
Log Severity: Warning (2)
Log Message: The Threshold Agent received an unknown action code from the service. The data
contains the action code.
Event identifier: cpqhsmsg.dll - 2317 (Hex)0x8435090d (Service Event)
Log Severity: Warning (2)
Log Message: The Threshold Agent could not get the system type. The data contains the error code.
Event identifier: cpqhsmsg.dll - 2354 (Hex)0x84350932 (Service Event)
Log Severity: Warning (2)
Log Message: The Threshold Agent could not create an SNMP session. The data contains the error
code.
Event identifier: cpqhsmsg.dll - 2355 (Hex)0x84350933 (Service Event)
Log Severity: Warning (2)
Log Message: The Threshold Agent SNMP request failed. The data contains the error code. Action:
1) Be sure that the SNMP service is configured to allow SNMP requests from “localhost. 2) Be
sure that there is an adequate amount of free memory.
Event identifier: cpqhsmsg.dll - 2356 (Hex)0x84350934 (Service Event)
Log Severity: Warning (2)
Log Message: “%1”. The data contains the error code.
Event identifier: cpqhsmsg.dll - 2357 (Hex)0x84350935 (Service Event)
Log Severity: Warning (2)
Log Message: The Threshold Agent could not set the variable because it is unsupported. The data
contains the error code.
Event identifier: cpqhsmsg.dll - 2358 (Hex)0x84350936 (Service Event)
Log Severity: Warning (2)
Log Message: The Threshold Agent could not set the variable because the value is invalid or out
of range. The data contains the error code.
Event identifier: cpqhsmsg.dll - 2359 (Hex)0x84350937 (Service Event)
Log Severity: Warning (2)
Log Message: The Threshold Agent is not loaded. Sets are not available. The data contains the
error code.
Event Identifiers 3072-3876
Event identifier: cpqhsmsg.dll - 3072 (Hex)0x84350c00 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read from the registry sub-key. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 3073 (Hex)0x84350c01 (Service Event)
Log Severity: Warning (2)
Log Message: Could not create the registry sub-key: “%1”. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.