HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide

Log Severity: Error (3)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in slot %4, port %5, bay %6 has a new status of %2.
SNMP Trap: cpqDa4SpareStatusChange - 3017 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in
the status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare
drive status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaSpareStatus
cpqDaSpareCntlrIndex
cpqDaSpareBusNumber
cpqDaSpareBay
Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].
NT Event ID: 1064 (Hex)0xc4350428 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Physical Drive Status Change.
Log Message: The physical drive in slot %4, port %5, bay %6 with serial number “%7”, has a new
status of %2.
SNMP Trap: cpqDa5PhyDrvStatusChange - 3029 in CPQIDA.MIB
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change
in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current
physical drive status.
User Action: If the physical drive status is failed(3) or predictiveFailure(4), replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaPhyDrvStatus
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvBusNumber
cpqDaPhyDrvBay
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
cpqDaPhyDrvFailureCode
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].
NT Event ID: 1065 (Hex)0xc4350429 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Accelerator Status Change.
Event Identifiers 1061-1098 29