HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqSsChassisName
• cpqSsChassisTime
• cpqFcaLogDrvBoxIndex
• cpqFcaLogDrvIndex
• cpqFcaLogDrvStatus
• cpqFcaLogDrvOsName
• cpqFcaLogDrvFaultTol
• cpqFcaLogDrvSize
Supporting SNMP Trap Description: “Status is now [cpqFcaLogDrvStatus].”
NT Event ID: 1146 (Hex)0xc435047a (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Physical Drive Status Change.
Log Message: The physical drive in port %5, bay %6 on array “%4” has a new status of %7.
SNMP Trap: cpqFca2PhyDrvStatusChange - 16016 in CPQFCA.MIB
Symptom: External Array Physical Drive Status Change. This trap indicates that the agent has
detected a change in the status of a physical drive. The variable cpaFcaPhyDrvStatus indicates the
current physical drive status.
User Action: If the physical drive status is threshExceeded(4), predictiveFailure(5) or failed(6),
replace the drive.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqSsChassisName
• cpqSsChassisTime
• cpqFcaPhyDrvBusNumber
• cpqFcaPhyDrvBay
• cpqFcaPhyDrvStatus
• cpqFcaPhyDrvModel
• cpqFcaPhyDrvSerialNum
• cpqFcaPhyDrvFWRev
• cpqFcaPhyDrvFailureCode
Supporting SNMP Trap Description: “Status is now [cpqFcaPhyDrvStatus] for a physical drive on
bus [cpqFcaPhyDrvBusNumber], bay [cpqFcaPhyDrvBay].”
NT Event ID: 1147 (Hex)0xc435047b (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Spare Drive Status Change.
Log Message: The spare drive in port %5, bay %6 on array “%4” has a new status of %7.
SNMP Trap: cpqFcaSpareStatusChange - 16002 in CPQFCA.MIB