HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide

Event Title: External Tape Drive Cleaning Required.
Log Message: The tape drive at location “%4” requires cleaning.
SNMP Trap: cpqExtTapeDriveCleaningRequired - 16024 in CPQFCA.MIB
Symptom: External Tape Drive Cleaning Required trap. The agent has detected a tape drive that
needs to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqFcTapeDriveCntlrIndex
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun
cpqFcTapeDriveModel
cpqFcTapeDriveFWRev
cpqFcTapeDriveSerialNumber
cpqFcTapeDriveLocation
Supporting SNMP Trap Description: “Cleaning is needed for tape drive.
NT Event ID: 1195 (Hex)0x843504ab (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: External Tape Drive Replace Cleaning Tape.
Log Message: The cleaning tape in the tape drive at location “%4” needs to be replaced.
SNMP Trap: cpqExtTapeDriveCleanTapeReplace - 16025 in CPQFCA.MIB
Symptom: External Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an
autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be
replaced with a new cleaning tape.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqFcTapeDriveCntlrIndex
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun
cpqFcTapeDriveModel
cpqFcTapeDriveFWRev
cpqFcTapeDriveSerialNumber
cpqFcTapeDriveLocation
Supporting SNMP Trap Description: “Cleaning tape needs replacing.
NT Event ID: 1196 (Hex)0x843504ac (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Recovery Server Option Status Change.
Log Message: Storage system “%4” has a new RSO status of %5.
Event Identifiers 1101-1199 55