HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide

NT Event ID: 1210 (Hex)0x843504ba (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Cleaning Required.
Log Message: The tape drive in %4, SCSI bus %5, SCSI target %6 requires cleaning.
SNMP Trap: cpqDa6TapeDriveCleaningRequired - 3044 in CPQIDA.MIB
Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to
have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaTapeDrvCntlrIndex
cpqDaTapeDrvBusIndex
cpqDaTapeDrvScsiIdIndex
cpqDaTapeDrvLunIndex
cpqDaTapeDrvName
cpqDaTapeDrvFwRev
cpqDaTapeDrvSerialNumber
Supporting SNMP Trap Description: “Cleaning is needed for the tape drive.
NT Event ID: 1211 (Hex)0x843504bb (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Drive Replace Cleaning Tape.
Log Message: The cleaning tape in the tape drive in %4, SCSI bus %5, SCSI target %6 needs to
be replaced.
SNMP Trap: cpqDa6TapeDriveCleanTapeReplace - 3045 in CPQIDA.MIB
Symptom: Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader
tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a
new cleaning tape.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaTapeDrvCntlrIndex
cpqDaTapeDrvBusIndex
cpqDaTapeDrvScsiIdIndex
cpqDaTapeDrvLunIndex
cpqDaTapeDrvName
cpqDaTapeDrvFwRev
cpqDaTapeDrvSerialNumber
Supporting SNMP Trap Description: “Cleaning tape needs replacing.
NT Event ID: 1212 (Hex)0x843504bc (cpqstmsg.dll)
Event Identifiers 1200-1294 63