HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide

cpqSsBoxCntlrHwLocation
cpqSsBoxCntlrIndex
cpqSsBoxBusIndex
cpqSsBoxVendor
cpqSsBoxModel
cpqSsBoxSerialNumber
cpqSsBoxTempStatus
cpqSsBoxLocationString
Supporting SNMP Trap Description: “Storage System temperature status changed to
[cpqSsBoxTempStatus].
NT Event ID: 1220 (Hex)0x843504c4 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fault Tolerant Power Supply Status Change.
Log Message: The fault tolerant power supply in the %6 %7 storage system connected to %5 of
the controller in%4 has a new status of %2.
SNMP Trap: cpqSs6PwrSupplyStatusChange - 8031 in CPQSTSYS.MIB
Symptom: Storage System Fault Tolerant Power Supply Status Change. The agent has detected a
change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus
indicates the current power supply status.
User Action: If the power supply status is degraded, restore power or replace the failed power
supply.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxCntlrHwLocation
cpqSsBoxCntlrIndex
cpqSsBoxBusIndex
cpqSsBoxVendor
cpqSsBoxModel
cpqSsBoxSerialNumber
cpqSsBoxFltTolPwrSupplyStatus
cpqSsBoxLocationString
Supporting SNMP Trap Description: “Storage System power supply status changed to
[cpqSsBoxFltTolPwrSupplyStatus].
NT Event ID: 1221 (Hex)0x843504c5 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SAS/SATA Physical Drive Status Change.
Log Message: The physical drive in %4, %5 with serial number “%6”, has a new status of %7.
SNMP Trap: cpqSasPhyDrvStatusChange - 5022 in CPQSCSI.MIB
Symptom: Physical Drive Status Change. The Storage Agent has detected a change in the status
of a SAS or SATA physical drive. The current physical drive status is indicated in the
cpqSasPhyDrvStatus variable.
68 Storage agents