HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide

User Action: If the physical drive status is predictiveFailure(3), failed(5), ssdWearOut(10) or,
notAuthenticated(12) replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSasHbaHwLocation
cpqSasPhyDrvLocationString
cpqSasPhyDrvHbaIndex
cpqSasPhyDrvIndex
cpqSasPhyDrvStatus
cpqSasPhyDrvType
cpqSasPhyDrvModel
cpqSasPhyDrvFWRev
cpqSasPhyDrvSerialNumber
cpqSasPhyDrvSasAddress
Supporting SNMP Trap Description: “Status is now [cpqSasPhyDrvStatus].
NT Event ID: 1222 (Hex)0x843504c6 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SAS/SATA Logical Drive Status Change.
Log Message: Logical drive number %5 on the HBA in %4 has a new status of %6.
SNMP Trap: cpqSasLogDrvStatusChange - 5023 in CPQSCSI.MIB
Symptom: Logical Drive Status Change. The Storage Agent has detected a change in the status of
a SAS or SATA logical drive. The current logical drive status is indicated in the cpqSasLogDrvStatus
variable.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSasHbaHwLocation
cpqSasLogDrvHbaIndex
cpqSasLogDrvIndex
cpqSasLogDrvStatus
cpqSasLogDrvOsName
Supporting SNMP Trap Description: “Status is now [cpqSasLogDrvStatus].
NT Event ID: 1223 (Hex)0x843504c7 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SAS Tape Drive Status Change.
Log Message: The tape drive in %4, %5 with serial number "%6", has a new status of %7. (Tape
Drive status values: 1=other, 2=ok, 3=offline)
SNMP Trap: cpqSas2TapeDrvStatusChange - 5025 in CPQSCSI.MIB
Symptom: The Storage Agent has detected a change in the status of a SAS tape drive. The current
tape drive status is indicated in the cpqSasTapeDrvStatus variable.
Supporting SNMP Trap Data
Event Identifiers 1200-1294 69