HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide

cpqSeCpuUnitIndex
cpqSeCpuSlot
cpqSeCpuName
cpqSeCpuSpeed
cpqSeCpuStep
cpqSeCpuStatus
cpqSeCpuExtSpeed
cpqSeCpuSocketNumber
cpqSeCpuHwLocation
Supporting SNMP Trap Description: “Processor in Slot [cpqSeCpuSlot] status change to
[cpqSeCpuStatus].
SNMP Trap: cpqSeCpuPowerPodstatusChange - 1007 in CPQSTDEQ.MIB
Symptom: This Trap is sent if CPU Power Pod status changes.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSeCpuUnitIndex
cpqSeCpuSlot
cpqSeCpuName
cpqSeCpuSpeed
cpqSeCpuStep
cpqSeCpuPowerpodStatus
cpqSeCpuExtSpeed
cpqSeCpuSocketNumber
cpqSeCpuHwLocation
Supporting SNMP Trap Description: “Processor in Slot [cpqSeCpuSlot] Power supply status is
[cpqSeCpuPowerpodStatus].
NT Event ID: 1115 (Hex)0x8435045b (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: A computer cover has been removed since last system start up. Be sure the system
cover is installed properly. This situation may result in improper cooling of the system due to air
flow changes caused by the missing cover.
SNMP Trap: cpqSiHoodRemoved - 2001 in CPQSINFO.MIB
Symptom: The access panel is removed. The access panel status has been set to removed. The
access panel is not installed properly. This situation may result in improper cooling of the system
due to air flow changes caused by the missing access panel.
User Action: Replace the access panel and be sure that it is installed properly. Verify that the system
is working properly.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Event Identifiers 1103-1183 89