HP Insight Management Agents 9.0 Microsoft Windows Event ID and SNMP Traps Reference Guide

to reflect the new rack name. It may take several minutes for the rack name change to be propagated
throughout the entire rack.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackSerialNum
cpqRackTrapSequenceNum
Supporting SNMP Trap Description: “The rack name has changed to [cpqRackName].
NT Event ID: 1144 (Hex)0x44350478 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: Rack Enclosure Name Changed.
SNMP Trap: cpqRackEnclosureNameChanged - 22002 in CPQRACK.MIB
Symptom: The enclosure name has changed. This trap indicates that an agent or utility has changed
the name of an enclosure within the rack. Each of the components within the rack is updated to
reflect the new enclosure name. It may take several minutes for the enclosure name change to be
propagated throughout the entire enclosure.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureModel
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure name has changed to
[cpqRackCommonEnclosureName] in rack [cpqRackName].
NT Event ID: 1145 (Hex)0x44350479 (cpqsvmsg.dll)
Log Severity: Information (1)
Event Title: Enclosure Removed
Log Message: This trap indicates that an enclosure has been removed from the rack.
SNMP Trap: cpqRackEnclosureRemoved - 22003 in CPQRACK.MIB
Symptom: The enclosure has been removed. This trap indicates that an enclosure has been removed
from the rack.
User Action: None.
98 Server agents