Table 7 Sub-agents of the Storage Agent (continued)
DescriptionSub-agent
ATAPI device information
SATA devices
The IDE Agent is located in /opt/hp/hp-snmp-agents/storage/bin/cmaided.
The suggested poll_time is 15 seconds (default). The minimum recommended poll_time
is 5 seconds.
The FCA Agent gathers data for the FCA MIB. The data includes:FCA Agent (cmafcad)
FCA host controller information
FCA array controller information
FCA array accelerator information
FCA logical drive information
FCA physical drive information
FCA storage system chassis information
FCA storage system power supply information
FCA storage system fan information
FCA storage system temperature information
FCA storage system backplane information
The FCA Agent is located in /opt/hp/hp-snmp-agents/storage/bin/cmafcad.
The suggested poll_time is 15 seconds (default). The minimum recommended poll_time
is 5 seconds.
The SCSI Agent gathers data for the SCSI MIB. The data includes:SCSI Agent (cmascsid)
SCSI host controller information
SCSI disk drive information
SCSI tape drive information
The SCSI Agent is located in /opt/hp/hp-snmp-agents/storage/bin/cmascsid.
The suggested poll_time is 15 seconds. The minimum recommended poll_time is 5
seconds.
The SAS Agent gathers data for the SAS MIB. The data includes:SAS Agent (cmasasd)
SAS host controller information
SAS disk drive information
SAS tape drive information
The SAS Agent is located in /opt/hp/hp-snmp-agents/storage/bin/cmasasd.
The suggested poll_time is 15 seconds. The minimum recommended poll_time is 5
seconds.
The Event Daemon gathers storage hardware events from the firmware and passes them
on to other agents upon request. The Event Daemon is located in
/opt/hp/hp-snmp-agents/storage/bin/cmaeventd.
Event Daemon (cmaeventd)
NIC agent (cmanic)
The NIC Agent collects information from network interface controllers at periodic intervals, makes
the collected data available to the SNMP agent, and provides SNMP alerts. The NIC Agent gathers
data for the NIC MIB from supported NIC device drivers. The data includes:
Physical mapping and configuration data for each network interface
Network statistics for Ethernet interfaces. Information is provided for HP controllers. Limited
information may be provided for third-party NICs