Microsoft Windows Event ID and SNMP Traps Reference Guide

Log Message: The server blade has been inserted from the enclosure.
SNMP Trap: cpqRackServerBladeInserted - 22029 in CPQRACK.MIB
Symptom: Server blade inserted. The server blade has been inserted into the enclosure.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackServerBladeEnclosureName
cpqRackServerBladeName
cpqRackServerBladePosition
cpqRackServerBladeSparePartNumber
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Server blade [cpqRackServerBladeName] inserted into
position [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack
[cpqRackName].
NT Event ID: 1172 (Hex)0x84350494 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Rack Power Subsystem Not Load Balanced
Log Message: The power subsystem is out of balance for this power enclosure.
SNMP Trap: cpqRackPowerChassisNotLoadBalanced - 22030 in CPQRACK.MIB
Symptom: Power subsystem not load balanced. The power subsystem is out of balance for this
power enclosure.
User Action: Check the power enclosure and power supplies. Replace any failed or degraded
power supplies. Add additional power supplies if needed.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “Power subsystem not load balanced in enclosure
[cpqRackCommonEnclosureName], in rack [cpqRackName].
NT Event ID: 1173 (Hex)0x84350495 (cpqsvmsg.dll)
Log Severity: Warning (2)
Event Title: Power Subsystem DC Power Problem
Log Message: There is a power subsystem DC power problem for this enclosure.
112 Server agents