Microsoft Windows Event ID and SNMP Traps Reference Guide

Event identifier: cpqstmsg.dll - 773 (Hex)0xc4350305 (Service Event)
Log Severity: Error (3)
Log Message: The Remote Alerter Agent received an error on WaitForMultipleObjects call. The
data contains the error code.
Event identifier: cpqstmsg.dll - 774 (Hex)0xc4350306 (Service Event)
Log Severity: Error (3)
Log Message: The Remote Alerter Agent received an error on ResetEvent call. The data contains
the error code.
Event Identifiers 1061-1098
NT Event ID: 1061 (Hex)0xc4350425 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Physical Drive Threshold Exceeded.
Log Message: The physical drive in slot %4, port %5, bay %6 with serial number “%7”, has
exceeded a drive threshold.
SNMP Trap: cpqDa5PhyDrvThreshPassedTrap - 3030 in CPQIDA.MIB
Symptom: Physical Drive Threshold Passed. This trap indicates that the agent has detected a factory
threshold associated with one of the physical drive objects on a drive array, has been exceeded.
User Action: Replace the physical drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvBusNumber
cpqDaPhyDrvBay
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
Supporting SNMP Trap Description: “Factory threshold passed for a physical drive.
NT Event ID: 1062 (Hex)0xc4350426 (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Logical Drive Status Change.
Log Message: Logical drive number %5 on the array controller in slot %4 has a new status of %2.
SNMP Trap: cpqDa3LogDrvStatusChange - 3008 in CPQIDA.MIB
Symptom: Logical Drive Status Change. This trap indicates that the agent has detected a change
in the status of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current
logical drive status.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaLogDrvStatus
Supporting SNMP Trap Description: “Status is now [cpqDaLogDrvStatus].
NT Event ID: 1063 (Hex)0xc4350427 (cpqstmsg.dll)
28 Storage agents