Microsoft Windows Event ID and SNMP Traps Reference Guide

Log Message: The array accelerator board attached to the array controller in slot %4 has a new
status of %2.
SNMP Trap: cpqDa5AccelStatusChange - 3025 in CPQIDA.MIB
Symptom: Accelerator Board Status Change. This trap indicates that the agent has detected a
change in the status of an array accelerator cache board. The current status is represented by the
variable cpqDaAccelStatus.
User Action: If the accelerator board status is permDisabled(5), you may need to replace the
accelerator board.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrSlot
cpqDaCntlrModel
cpqDaAccelSerialNumber
cpqDaAccelTotalMemory
cpqDaAccelStatus
cpqDaAccelErrCode
Supporting SNMP Trap Description: “Status is now [cpqDaAccelStatus].
NT Event ID: 1066 (Hex)0xc435042a (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Accelerator Bad Data.
Log Message: The array accelerator board attached to the array controller in slot %4 is reporting
that it contains bad cached data.
SNMP Trap: cpqDa5AccelBadDataTrap - 3026 in CPQIDA.MIB
Symptom: Accelerator Board Bad Data. This trap indicates that the agent has detected an array
accelerator cache board that has lost battery power. If data was being stored in the accelerator
cache memory when the server lost power, that data has been lost.
User Action: Verify that no data has been lost.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrSlot
cpqDaCntlrModel
cpqDaAccelSerialNumber
cpqDaAccelTotalMemory
Supporting SNMP Trap Description: Accelerator lost battery power. Data Loss possible.
NT Event ID: 1067 (Hex)0xc435042b (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: Drive Array Accelerator Battery Failed.
Log Message: The array accelerator board attached to the array controller in slot %4 is reporting
a battery failure.
SNMP Trap: cpqDa5AccelBatteryFailed - 3027 in CPQIDA.MIB
30 Storage agents