Microsoft Windows Event ID and SNMP Traps Reference Guide

Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaLogDrvBoxIndex
cpqFcaLogDrvIndex
cpqFcaLogDrvStatus
cpqFcaLogDrvOsName
cpqFcaLogDrvFaultTol
cpqFcaLogDrvSize
Supporting SNMP Trap Description: “Status is now [cpqFcaLogDrvStatus].
NT Event ID: 1146 (Hex)0xc435047a (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Physical Drive Status Change.
Log Message: The physical drive in port %5, bay %6 on array “%4” has a new status of %7.
SNMP Trap: cpqFca2PhyDrvStatusChange - 16016 in CPQFCA.MIB
Symptom: External Array Physical Drive Status Change. This trap indicates that the agent has
detected a change in the status of a physical drive. The variable cpaFcaPhyDrvStatus indicates the
current physical drive status.
User Action: If the physical drive status is threshExceeded(4), predictiveFailure(5) or failed(6),
replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaPhyDrvBusNumber
cpqFcaPhyDrvBay
cpqFcaPhyDrvStatus
cpqFcaPhyDrvModel
cpqFcaPhyDrvSerialNum
cpqFcaPhyDrvFWRev
cpqFcaPhyDrvFailureCode
Supporting SNMP Trap Description: “Status is now [cpqFcaPhyDrvStatus] for a physical drive on
bus [cpqFcaPhyDrvBusNumber], bay [cpqFcaPhyDrvBay].
NT Event ID: 1147 (Hex)0xc435047b (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Spare Drive Status Change.
Log Message: The spare drive in port %5, bay %6 on array “%4” has a new status of %7.
SNMP Trap: cpqFcaSpareStatusChange - 16002 in CPQFCA.MIB
Event Identifiers 1101-1199 37