Microsoft Windows Event ID and SNMP Traps Reference Guide

Symptom: External Array Spare Drive Status Change. This trap indicates that the agent has detected
a change in the status of an External Channel Array spare drive. The variable cpqFcaSpareStatus
indicates the current spare drive status. The variable cpqFcaSpareBusNumber indicates the SCSI
bus number associated with this drive.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaSpareBusNumber
cpqFcaSpareBay
cpqFcaSpareStatus
Supporting SNMP Trap Description: “Spare Status is now [cpqFcaSpareStatus] on bus
[cpqFcaSpareBusNumber].
NT Event ID: 1148 (Hex)0xc435047c (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Status Change.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of
array “%4” has a new status of %6.
SNMP Trap: cpqFca2AccelStatusChange - 16017 in CPQFCA.MIB
Symptom: External Array Accelerator Board Status Change. This trap indicates that the agent has
detected a change in the status of an Array Accelerator Cache Board. The current status is
represented by the variable cpqFcaAccelStatus.
User Action: If the accelerator board status is permDisabled(5), you may need to replace the
accelerator board.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaAccelBoxIoSlot
cpqFcaAccelStatus
cpqFcaCntlrModel
cpqFcaAccelSerialNumber
cpqFcaAccelTotalMemory
cpqFcaAccelErrCode
Supporting SNMP Trap Description: “Status is now [cpqFcaAccelStatus].
NT Event ID: 1149 (Hex)0xc435047d (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Accelerator Bad Data.
Log Message: The array accelerator board attached to the external controller in I/O slot %5 of
array “%4” is reporting that it contains bad cached data.
38 Storage agents