Microsoft Windows Event ID and SNMP Traps Reference Guide

Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsPowerSupplyBay
cpqSsPowerSupplyStatus
cpqSsPowerSupplySerialNumber
cpqSsPowerSupplyBoardRevision
cpqSsPowerSupplyFirmwareRevision
Supporting SNMP Trap Description: “Storage system power supply status changed to
[cpqSsPowerSupplyStatus].
NT Event ID: 1154 (Hex)0x84350482 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Power Supply UPS Status Change.
Log Message: The UPS attached to storage system “%4” power supply bay %5 has a new status
of %7.
SNMP Trap: cpqSsExPowerSupplyUpsStatusChange - 8018 in CPQSTSYS.MIB
Symptom: Storage system power supply UPS status change. The agent has detected a change
status of a UPS attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus
indicates the current status.
User Action: If the UPS status is powerFailed(4) or batteryLow(5), restore power to the UPS.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsPowerSupplyBay
cpqSsPowerSupplyUpsStatus
Supporting SNMP Trap Description: “Storage system power supply UPS status changed to
[cpqSsPowerSupplyUpsStatus].
NT Event ID: 1155 (Hex)0x84350483 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Temperature Sensor Status Change.
Log Message: Storage system “%4” temperature sensor at location %5 has a new status of %6
and a current temperature value of %7 celsius.
SNMP Trap: cpqSsExTempSensorStatusChange - 8019 in CPQSTSYS.MIB
Symptom: Storage system temperature sensor status change. The agent has detected a change in
the status of a storage system temperature sensor. The variable cpqSsTempSensorStatus indicates
the current status.
User Action: If the temperature status is degraded or failed, shut down the storage system as soon
as possible. Be sure that the storage system environment is being cooled properly and that no
components are overheated.
Event Identifiers 1101-1199 41