Microsoft Windows Event ID and SNMP Traps Reference Guide

User Action: If the physical drive status is smartError(3), failed(4) or, ssdWearOut(5) replace the
drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqIdeAtaDiskControllerIndex
cpqIdeAtaDiskIndex
cpqIdeAtaDiskModel
cpqIdeAtaDiskFwRev
cpqIdeAtaDiskSerialNumber
cpqIdeAtaDiskStatus
cpqIdeAtaDiskChannel
cpqIdeAtaDiskNumber
Supporting SNMP Trap Description: “Status is now [cpqIdeAtaDiskStatus] for the ATA disk.
NT Event ID: 1187 (Hex)0x843504a3 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: ATA RAID Logical Drive Status Change.
Log Message: ATA RAID logical drive number %6 on the “%5” in slot %4 has a new status of %2.
SNMP Trap: cpqIdeLogicalDriveStatusChange - 14005 in CPQIDE.MIB
Symptom: IDE Logical Drive Status Change. This trap indicates that the agent has detected a change
in the status of an IDE logical drive. The variable cpqIdeLogicalDriveStatus indicates the current
logical drive status.
User Action: If the logical drive status is failed(5), examine the array for failed drives that need
replacement.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqIdeControllerModel
cpqIdeControllerSlot
cpqIdeLogicalDriveControllerIndex
cpqIdeLogicalDriveIndex
cpqIdeLogicalDriveStatus
Supporting SNMP Trap Description: “Status is now [cpqIdeLogicalDriveStatus] for the IDE logical
drive.
NT Event ID: 1188 (Hex)0x843504a4 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: An enclosure attached to port %5 of storage system “%4” has a new fan status of
%7. The enclosure model is “%6”.
SNMP Trap: cpqSsExBackplaneFanStatusChange - 8022 in CPQSTSYS.MIB
Symptom: Storage System Fan Status Change. The agent has detected a change in the fan status
of a storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status.
Event Identifiers 1101-1199 51