Microsoft Windows Event ID and SNMP Traps Reference Guide
Log Message: The array accelerator board attached to the array controller in %4 is reporting a
battery failure.
SNMP Trap: cpqDa6AccelBatteryFailed - 3040 in CPQIDA.MIB
Symptom: Accelerator Board Battery Failed. This trap indicates that the agent has detected a battery
failure associated with the array accelerator cache board.
User Action: Replace the Accelerator Cache Board.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqDaCntlrHwLocation
• cpqDaCntlrModel
• cpqDaAccelCntlrIndex
• cpqDaAccelSerialNumber
• cpqDaAccelTotalMemory
Supporting SNMP Trap Description: “Battery status is failed.”
NT Event ID: 1207 (Hex)0x843504b7 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Library Status Change.
Log Message: The tape library in %4, SCSI bus %5, SCSI target %6 has a new status of %7.
SNMP Trap: cpqDa6TapeLibraryStatusChange - 3041 in CPQIDA.MIB
Symptom: Tape Library Status Change. This trap indicates that the agent has detected a change
in the status of a tape library. The variable cpqDaTapeLibraryStatus indicates the current tape
library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library.
User Action: If the tape library is failed, check the tape library front panel.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqDaCntlrHwLocation
• cpqDaTapeLibraryCntlrIndex
• cpqDaTapeLibraryScsiBus
• cpqDaTapeLibraryScsiTarget
• cpqDaTapeLibraryScsiLun
• cpqDaTapeLibraryModel
• cpqDaTapeLibraryFWRev
• cpqDaTapeLibrarySerialNumber
• cpqDaTapeLibraryStatus
Supporting SNMP Trap Description: “Status is now [cpqDaTapeLibraryStatus] for the tape library.”
NT Event ID: 1208 (Hex)0x843504b8 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Tape Library Door Status Change.
Log Message: The tape library in %4, SCSI bus %5, SCSI target %6 has a new door status of %7.
Event Identifiers 1200-1294 61