Microsoft Windows Event ID and SNMP Traps Reference Guide

Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has
a new status of %2.
SNMP Trap: cpqSs5FanStatusChange - 8026 in CPQSTSYS.MIB
Symptom: Storage System fan status change. The agent has detected a change in the Fan Status
of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
User Action: If the fan status is degraded or failed, replace any failed fans.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxCntlrHwLocation
cpqSsBoxCntlrIndex
cpqSsBoxBusIndex
cpqSsBoxVendor
cpqSsBoxModel
cpqSsBoxSerialNumber
cpqSsBoxFanStatus
Supporting SNMP Trap Description: “Storage System fan status changed to [cpqSsBoxFanStatus].
NT Event ID: 1213 (Hex)0x843504bd (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Temperature Status Change.
Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has
a new temperature status of %2.
SNMP Trap: cpqSs5TempStatusChange - 8027 in CPQSTSYS.MIB
Symptom: Storage System Temperature Status Change. The agent has detected a change in the
temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current
temperature status.
User Action: If the temperature status is degraded or failed, shut down the storage system as soon
as possible. Be sure that the storage system environment is being cooled properly and that no
components are overheated.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsBoxCntlrHwLocation
cpqSsBoxCntlrIndex
cpqSsBoxBusIndex
cpqSsBoxVendor
cpqSsBoxModel
cpqSsBoxSerialNumber
cpqSsBoxTempStatus
64 Storage agents