Microsoft Windows Event ID and SNMP Traps Reference Guide

cpqFcaHostCntlrWorldWideName
cpqFcaHostCntlrWorldWidePortName
Supporting SNMP Trap Description: “Host controller has a new status of [cpqFcaHostCntlrStatus].
NT Event ID: 1216 (Hex)0x843504c0 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive Status Change.
Log Message: The physical drive in %4, %5 with serial number “%7”, has a new status of %2.
SNMP Trap: cpqDa7PhyDrvStatusChange - 3046 in CPQIDA.MIB
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change
in the status of a drive array physical drive. The variable cpqDaPhyDrvStatus indicates the current
physical drive status.
User Action: If the physical drive status is failed(3), predictiveFailure(4), ssdWearOut(8), or
notAuthenticated(9), replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvIndex
cpqDaPhyDrvLocationString
cpqDaPhyDrvType
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
cpqDaPhyDrvFailureCode
cpqDaPhyDrvStatus
cpqDaPhyDrvBusNumber
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].
NT Event ID: 1217 (Hex)0x843504c1 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in %4, %5 has a new status of %2.
SNMP Trap: cpqDa7SpareStatusChange - 3047 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in
the status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare
drive status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
66 Storage agents