Microsoft Windows Event ID and SNMP Traps Reference Guide

{ sysName, cpqHoTrapFlags, cpqSasHbaHwLocation,
cpqSasTapeDrvLocationString, cpqSasTapeDrvHbaIndex,
cpqSasTapeDrvIndex, cpqSasTapeDrvName,
cpqSasTapeDrvFWRev, cpqSasTapeDrvSerialNumber,
cpqSasTapeDrvSasAddress, cpqSasTapeDrvStatus }
NT Event ID: 1224 (Hex)0x843504c8 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Partner Controller Status Change.
Log Message: The Drive Array Controller in %4 has a Drive Array Partner Controller with serial
number %5. This Partner Controller has a new status of %2. (Partner Controller status values:
1=other, 2=ok, 3=generalFailure)
SNMP Trap: cpqDaCntlrPartnerStatusChange - 3048 in CPQIDA.MIB
Symptom: The agent has detected a change in the status of a drive array partner controller. The
variable cpqDaCntlrPartnerBoardStatus indicates the current partner controller status. The variable
cpqDaCntlrSerialNumber indicates the controller’s serial number and
cpqDaCntlrPartnerSerialNumber indicates the partner controller’s serial number
User Action: Check the partner controller for problems. If lost communication with the partner
controller is the result of a user initiated action, no remedial action is required.
Supporting SNMP Trap Data
{sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
cpqDaCntlrIndex, cpqDaCntlrModel,
cpqDaCntlrSerialNumber, cpqDaCntlrPartnerSerialNumber,
cpqDaCntlrPartnerBoardStatus}
NT Event ID: 1225 (Hex)0x843504c9 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Connection Status Change.
Log Message: The %7 storage system connected to %5 of the controller in %4 has a new connection
status of %6. (Connection status values: 1=other, 2=notSupported, 3=connected, 4=notConnected)
SNMP Trap: cpqSsConnectionStatusChange - 8032 in CPQSTSYS.MIB
Symptom: The agent has detected a change in the connection status of a storage system. The
variable cpqSSboxConnectionStatus indicates the current connection status.
User Action: If the connection status is disconnected, take action to restore the connection between
the HBA and the storage system.
Supporting SNMP Trap Data
{sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
cpqSsBoxModel, cpqSsBoxSerialNumber, cpqSsBoxConnectionStatus,
cpqSsBoxLocationString, cpqSsBoxTargetSasAddress,
cpqSsBoxLocalManageIpAddress}
NT Event ID: 1226 (Hex)0x843504ca (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SAS/SATA Physical Drive SSD Wear Status Change.
Log Message: The physical drive in %4, %5 with serial number "%6", has a new solid state wear
status of %7. (Drive status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold,
5=twoPercentThreshold, 6=ssdWearOut)
SNMP Trap: cpqSasPhyDrvSSDWearStatusChange - 5026 in CPQSCSI.MIB
Symptom: The agent has detected a change in the SSD wear status of a SAS or SATA physical
drive. The variable cpqSasPhyDrvSSDWearStatus indicates the current SSD wear status.
User Action: If the SSD wear status is ssdWearOut(6), replace the drive.
70 Storage agents