Microsoft Windows Event ID and SNMP Traps Reference Guide

Supporting SNMP Trap Data
{ sysName, cpqHoTrapFlags, cpqSasHbaHwLocation,
cpqSasPhyDrvLocationString, cpqSasPhyDrvHbaIndex,
cpqSasPhyDrvIndex, cpqSasPhyDrvType, cpqSasPhyDrvModel,
cpqSasPhyDrvFWRev, cpqSasPhyDrvSerialNumber,
cpqSasPhyDrvSasAddress, cpqSasPhyDrvSSDWearStatus}
NT Event ID: 1227 (Hex)0x843504cb (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive SSD Wear Status Change.
Log Message: The physical drive in %4, %5 with serial number "%6", has a new solid state wear
status of %7. (Drive status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold,
5=twoPercentThreshold, 6=ssdWearOut)
SNMP Trap: cpqDaPhyDrvSSDWearStatusChange- 3049 in CPQIDA.MIB
Symptom: This trap signifies that the agent has detected a change in the SSD wear status of a drive
array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear
status.
User Action: If the SSD wear status is ssdWearOut(6), replace the drive.
Supporting SNMP Trap Data
{ sysName, cpqHoTrapFlags, cpqDaCntlrHwLocation,
cpqDaPhyDrvCntlrIndex, cpqDaPhyDrvIndex,
cpqDaPhyDrvLocationString, cpqDaPhyDrvType,
cpqDaPhyDrvModel, cpqDaPhyDrvFWRev, cpqDaPhyDrvSerialNum,
cpqDaPhyDrvSSDWearStatus}
NT Event ID: 1228 (Hex)0x843504cc (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: IDE Disk SSD Wear Status Change.
Log Message: The ATA disk drive with model %6 and serial number %7 has a new solid state
wear status of %2. (SSD wear status values: 1=other, 2=ok, 3=fiftySixDayThreshold,
4=fivePercentThreshold, 5=twoPercentThreshold, 6=ssdWearOut)
SNMP Trap: cpqIdeAtaDiskSSDWearStatusChange - 14006 in CPQIDE.MIB
Symptom: This trap signifies that the agent has detected a change in the SSD wear status of a
SATA physical drive. The variable cpqIdeAtaDiskSSDWearStatus indicates the current SSD wear
status.
User Action: If the SSD wear status is ssdWearOut(6), replace the drive.
Supporting SNMP Trap Data
{ sysName, cpqHoTrapFlags, cpqIdeAtaDiskControllerIndex,
cpqIdeAtaDiskIndex, cpqIdeAtaDiskModel,
cpqIdeAtaDiskFwRev, cpqIdeAtaDiskSerialNumber,
cpqIdeAtaDiskSSDWearStatus, cpqIdeAtaDiskChannel,
cpqIdeAtaDiskNumber}
Event identifier: cpqstmsg.dll - 1280 (Hex)0x84350500 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the
system will correct this error.
Event identifier: cpqstmsg.dll - 1281 (Hex)0x84350501 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read from the registry subkey. This error can be caused by a corrupt
registry or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 1282 (Hex)0x84350502 (Service Event)
Log Severity: Warning (2)
Event Identifiers 1200-1294 71