Microsoft Windows Event ID and SNMP Traps Reference Guide

SNMP Trap: cpqHe3FltTolFanRedundancyLost - 6037 in CPQHLTH.MIB
Symptom: The Fault Tolerant Fans have lost redundancy for the specified chassis.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
Supporting SNMP Trap Description: “The Fans are no longer redundant on Chassis
[cpqHeFltTolFanChassis].
NT Event ID: 1132 (Hex)0x4435046c (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: Fan Inserted. A hot-plug fan has been inserted into the system.
SNMP Trap: cpqHe3FltTolFanInserted - 6038 in CPQHLTH.MIB
Symptom: A Fault Tolerant Fan has been inserted into the specified chassis and fan location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
cpqHeFltTolFanIndex
Supporting SNMP Trap Description: “The Fan Inserted on Chassis [cpqHeFltTolFanChassis], Fan
[cpqHeFltTolFanIndex].
NT Event ID: 1133 (Hex)0x8435046d (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Fan Removed. A hot-plug fan has been removed from the system.
SNMP Trap: cpqHe3FltTolFanRemoved - 6039 in CPQHLTH.MIB
Symptom: A Fault Tolerant Fan has been removed from the specified chassis and fan location.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
cpqHeFltTolFanIndex
Supporting SNMP Trap Description: “The Fan Removed on Chassis [cpqHeFltTolFanChassis], Fan
[cpqHeFltTolFanIndex].
NT Event ID: 1134 (Hex)0xc435046e (cpqsvmsg.dll)
Log Severity: Error (3)
Log Message: A Temperature Sensor Condition has been set to failed. The system will be shut
down due to this overheat condition.
SNMP Trap: cpqHe3TemperatureFailed - 6040 in CPQHLTH.MIB
Symptom: The temperature status has been set to failed in the specified chassis and location. The
system is shut down due to this condition.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
94 Server agents