Table 15-111 HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name Property implementation
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames
VariableNames[0]: FailureDescription
VariableNames[1]: LastFailureDescription
VariableNames[2]: DriveInterface
VariableTypes
VariableTypes[0]: 1 (String)
VariableTypes[1]: 1 (String)
VariableTypes[2]: 4 (uint16)
VariableValues
VariableValues[0]: Short Description of failure
VariableValues[1]: Short Description of last failure
VariableValues[2]: HPSA_DiskDrive.DriveInterface
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Physical Disk firmware version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer COMPAQ
HWSerialNumber Physical Disk Serial Number