HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 15-124 HPSA_DeviceIndication: Controller Battery status changed to not fully charged
Property name Property implementation
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string
15-4-16 Controller Battery Status Changed to FAILED
Table 15-39 HPSA_DeviceIndication: Controller Battery status changed to Failed
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description Controller Battery Status set to a status of Failed.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 8
ProviderName HP Smart Array
RecommendedActions Check battery connection - replace if necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Controller Battery Status set to Failed.
EventCategory 6 (Primary Storage)
ProbableCause 92 (battery failure)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication