Table 15-128 HPSA_DeviceIndication: Controller Cache status—Permanently Disabled
Property name Property implementation
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames
VariableNames[0]: FailureDescription
VariableNames[1]: CacheSizeTotal
VariableNames[2]: CacheSerialNumber
VariableTypes
VariableTypes[0]: 1 (String)
VariableTypes[1]: 5 (uint16)
VariableTypes[2]: 1 (String)
VariableValues
VariableValues[0]: Short Description of failure
VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer Array Controller Manufacturer string
HWSerialNumber Array Controller Serial Number
HP_DeviceIndication
DeviceModel Array Controller Model string