HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 15-134 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name Property implementation
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1 (String)
VariableValues Short description of failure
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
15-4-26 Enclosure Fan status changed to OK
Table 15-135 HPSA_DeviceIndication: Enclosure Fan status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication