HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 16-84 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name Property implementation
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor status Warning Condition
EventCategory 24 (Primary Storage Cooling)
ProbableCause 51 (Temperature Unacceptable)
ProbableCauseDescription Temperature Status Changed to Warning Condition
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1 (String)
VariableValues Short Description of failure
In some cases, the property VariableValues can have
N/A or “” values.
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name