A.05.70 HP Insight Remote Support Advanced Service Brief: Read Before Installing (October 2011, 5900-1724)

6
Table 1 Required Managed System Communication Protocols and Components for Insight RSA Services
Hardware Platform Required Protocols
Notes
Integrity Superdome 2
Onboard Administrator
WBEM and
WS-Man and
HTTPS
Discovery uses WS-Man and collections use HTTPS. The OA is
managed using WS-Man, but the Superdome 2 partitions are
managed using WBEM.
See the “Integrity Superdome 2 Server Configuration” chapter in the
Managed Systems Configuration Guide.
HP-UX WBEM
Install the proper WBEM providers on HP-UX. These generally are
part of the feature set of HP-UX and will update through patches and
software updates on the device as appropriate.
For Mission Critical support, the RS-ACC must be installed and
certificates exchanged for Advanced, Availability, and Performance
collections. Configuration collections use HTTPS and are certificate
based, using SMH and SIM credentials.
See the “HP-UX Server Configuration” chapter in the Managed
Systems Configuration Guide.
OpenVMS on Integrity WBEM and
ELMC
(SNMP optional)
Must install the OpenVMS WBEM provider.
Configuration collections only work when the WBEM providers are
installed and the credentials are properly configured.
Discovery can use SNMP or WBEM, therefore SNMP is an optional
component.
See the “OpenVMS Server Configuration” chapter in the Managed
Systems Configuration Guide.
OpenVMS on Alpha SNMP and
ELMC
Configuration collections are not available except when the
OpenVMS Alpha server is part of a SAN collection. (See Table 2.)
See the “OpenVMS Server Configuration” chapter in the Managed
Systems Configuration Guide.
Tru64 UNIX SNMP and
ELMC
Configuration collections are not available except when the Tru64
UNIX server is part of a SAN collection. (See Table 2.)
See the “Tru64 UNIX Server Configuration” chapter in the Managed
Systems Configuration Guide.
NonStop WBEM
Configuration collections are not supported.
See the “NonStop Server Configuration” chapter in the Managed
Systems Configuration Guide.
Neoview WBEM
Configuration collections are not supported.
Storage
EVA WBEM and
ELMC and
See the “Enterprise Virtual Array Configuration” chapter in the
Managed Systems Configuration Guide.
P4000 Storage Systems SNMP and
P4000 CLI
Install the P4000 Integration Module on the CMS.
See the “P4000 Storage System Configuration” chapter in the
Managed Systems Configuration Guide.
MSA1000 and
MSA1500
SNMP
Configuration collections are not available except when these MSA
models are part of a SAN collection. (See Table 2.)
See the “Modular Smart Array Configuration” chapter in the
Managed Systems Configuration Guide.
MSA23xx SNMP and
WBEM
Install the WBEM MSA2000 providers on the host device.
See the “Modular Smart Array Configuration” chapter in the
Managed Systems Configuration Guide.