A.05.80 HP Insight Remote Support Advanced and Remote Device Access Security Overview (October 2012)

Protocol Ports Source Destination Function Configurable Optional
can be configured to use TCP port 5989 to simplify firewall
settings.
StorageWorks P6000 (EVA) Storage Systems
Table D.4. EVA Connectivity - Firewall/Port Requirements
Protocol Ports Source Destination Function Configurable Optional
TCP 2372 CMS EVA CommandView - Storage Collections for EVA (HTTPS) No Required
TCP 5989 CMS Managed
Systems
Secured WBEM CI-MOM protocol over HTTPS/SOAP.
This port is used to communicate with WBEM end point
nodes.
Yes Required
TCP 7920 CMS Managed
Systems
The WEBES ELMC (formerly WCCProxy) process
communicates with the Director on this port. This is a
proprietary protocol. Any connections that exchange
username and passwords use SSL. Not all connections are
SSL.
No Required
TCP 50001 Managed
Systems
CMS HP SIM HTTPS/SOAP No Required
TCP 50002 Managed
Systems
CMS HP SIM HTTPS/SOAP with client certificate authentication No Required
TCP 50004 Managed
Systems
CMS WBEM event receiver (HTTP and HTTPS) Yes Required
ICMP N/A CMS Managed
Systems
Provides system reachability (ping) check during system
discovery and before other operations. Note that HP SIM
can be configured to use TCP port 5989 to simplify firewall
settings.
No Recommended
HP Insight Remote Support Advanced and Remote Device Access (A.05.80)Page 78 of 97
Security Overview
Appendix D: Summary of Network Ports for Storage