Insight Remote Support 7.0.9 Security White Paper

Appendix F: Summary of Network Ports for HP UPS Management Module
Connectivity
The following tables summarize all ports that might be used in Insight Remote Support for HP UPS Management Module
Connectivity. See Table A-1 for ports that are required for basic system operation.
F.1 HP UPS Management Module Connectivity
Table G.1 HP UPS Management Module Connectivity Connectivity - Firewall/Port Requirements
Protocol
Ports
Source
Destination
Function
Configurable
Optional
UDP
161
Hosting Device
Monitored
Systems
SNMP. This is the standard port used by SNMP
agents on monitored systems. The Hosting Device
sends requests to devices on this port.
Yes
Required
UDP
162
Monitored
Systems
Hosting Device
SNMP Trap. This is the standard port used by SNMP
managers for listening to traps.
Yes
Required