HP Integrity Virtual Machines Version 4.2 Release Notes
NOTE: LVM mirroring in a VM is supported with 0909 or later versions of HostAVIOStor (on
the VM Host) and GuestAVIOStor (on the guest).
Integrity VM Version
B.04.20
Integrity VM Version
B.04.10
Integrity VM Version
B.04.00
Integrity VM Version
A.03.50
Backing Store
• HP-UX 11i v3 built-in
multipathing
• • EMC PowerPath
with legacy DSFs
• HP-UX 11i v3
built-in
multipathing
• • EMC PowerPath
with legacy DSFs
• HP-UX 11i v3
built-in multipathing
• • EMC PowerPath
with legacy DSFs
• HP Secure Path
A-A/A-P
• EMC PowerPath
Whole Disk
(or LUN)
• HP-UX 11i v3 built-in
multipathing
• PVLinks
• EMC PowerPath
with legacy whole
disk DSF in a
Volume Group
• HP-UX 11i v3
built-in
multipathing
• PVLinks
• EMC PowerPath
with legacy whole
disk DSF in a
Volume Group
• HP-UX 11i v3
built-in multipathing
• PVLinks
• EMC PowerPath
with legacy whole
disk DSF in a
Volume Group
• PV Links
• EMC PowerPath
• HP Secure Path
A-A/A-P
LVM Logical
Volumes
• HP-UX 11i v3 built-in
multipathing
• EMC PowerPath
with legacy whole
disk DSF in a Disk
Group
• Symantec DMP
• HP-UX 11i v3
built-in
multipathing
• EMC PowerPath
with legacy whole
disk DSF in a Disk
Group
• Symantec DMP
• HP-UX 11i v3
built-in multipathing
• EMC PowerPath
with legacy whole
disk DSF in a Disk
Group
• Symantec DMP
• Symantec DMP
• EMC PowerPath
• HP Secure Path
A-A/A-P
VxVM Logical
Volumes
• HP-UX 11i v3 built-in
multipathing
• PVLinks
• EMC PowerPath
with legacy disk DSF
in a Volume Group
• Symantec DMP
• HP-UX 11i v3
built-in
multipathing
• PVLinks
• EMC PowerPath
with legacy disk
DSF in a Volume
Group
• Symantec DMP
• HP-UX 11i v3
built-in multipathing
• PVLinks
• EMC PowerPath
with legacy disk DSF
in a Volume Group
• Symantec DMP
• PV Links
• Symantec DMP
• EMC PowerPath
• HP Secure Path
A-A/A-P
VxFS files are not
supported backing
storage with AVIO for
version A.03.50
VxFS Files
11.7.3 EVA Series Firmware Requirement
The AVIO Storage Driver supports only Active-Active firmware types on EVA series (3000/5000
and 4000/6000/8000). Be sure that the following firmware revision levels are met before configuring
AVIO backing stores on these arrays:
• On EVA 4000/6000/8000, all released firmware revisions support Active-Active configuration.
Therefore, no action is necessary on these arrays.
• EVA 3000/5000 arrays need minimum firmware revisions of VCS v4.004 (Active-Active
firmware).
For more information about EVA firmware upgrades, see the HP Services EVA upgrade website:
http://hpswest.corp.hp.com/VCSUpgradeProgram.asp.
11.8 Network Interface Support
VM Host I/O is HP-UX based. Specific network interfaces are supported if they are supported
for the version of HP-UX in use on the VM Host system. The VM Host physical network interface
94 Integrity VM Support Policy