HP-UX Virtual Partitions Administrator's Guide (includes A.03.05 and A.04.05)

NOTE: If you have previously applied any patches specific to vPars, you will need to re-apply those
patches to the vPars product.
Upgrading Integrity Servers from the sx1000 to sx2000 Chipset
You can upgrade the following Integrity servers from the sx1000 to sx2000 chipsets:
rx7620 to rx7640
rx8620 to rx8640
Integrity Superdome
To perform the hardware upgrade, follow the process documented in the hardware upgrade
manual for your server.
CAUTION:
Upgrade Notes
vPars A.04.02 or later is required for vPars running on HP Integrity servers with the sx2000
chipset.
PHKL_34088 is also required for vPars running on HP Integrity servers with the sx2000
chipset.
The physical hardware upgrade from the rx7620 to rx7640 requires a cold-install of the OS
and therefore of vPars as well.
Only Hewlett-Packard qualified service personnel can perform hardware upgrades from
rx8620 to rx8640 or from Integrity/sx1000 Superdome to Integrity/sx2000 Superdome.
While performing the hardware upgrades, HP qualified service personnel will reference the
following documents when making the necessary HP-UX and vPars configuration changes:
HP I/O Hardware Upgrade Scripts Guide for HP Integrity Superdome/sx2000 Servers and HP-UX
Impacts on the Upgrade Process for the rx8620 to rx8640 Hardware Upgrade.
Be aware that instead of performing the upgrades for vPars, LVM, etc., you also have the
option of performing a cold-install on the post-upgrade hardware as if they were new systems
with no previous installations.
Hardware Path Changes
The upgrade changes the hardware paths. For the new hardware paths as well as the hardware
upgrade process, see the upgrade manual for your server. For reference, the changes are noted
in the tables at the end of this section:
“rx7620 to rx7640 Hardware Path Changes ” (page 108)
“rx8620 to rx8640 Hardware Path Changes ” (page 108)
“Integrity Superdome Hardware Path Changes (x=cell)” (page 108).
vPars Database Changes
As part of the upgrade process, HP qualified service personnel will need to make updates to
each virtual partition’s vPars database (vpdb) in nPars mode following the server hardware
changes. These and other necessary steps are described in the HP I/O Hardware Upgrade Scripts
Guide for HP Integrity Superdome/sx2000 Servers and HP-UX Impacts on the Upgrade Process for the
rx8620 to rx8640 Hardware Upgrade service documents.
Hardware Path Tables
The tables below show the new hardware paths. For details on the new hardware paths and
other hardware information, see the applicable hardware upgrade manuals for your server,
available at http://docs.hp.com.
Upgrading Integrity Servers from the sx1000 to sx2000 Chipset 107