HP-UX Virtual Partitions Administrator's Guide (includes A.05.02)

Installing, Updating, or Removing vPars and Upgrading Servers with vPars
Upgrading Backplanes from PCI to PCI-X
Chapter 4
109
Upgrading Backplanes from PCI to PCI-X
If you upgrade from the PCI to PCI-X backplane with the following server upgrades:
rp7410 to rp7420
the rp8400 to rp8420
Superdome
the hardware paths of the I/O devices will change. The I/O device paths are in the format
cell/sba/lba/device/function.target.lun
When changing from the PCI to PCI-X backplane, the device in the hardware paths will change from 0 to 1.
So, if a hardware path before the upgrade was
1/0/8/0/0.6.0
the new hardware path is
1/0/8/1/0.6.0
Not all I/O hardware paths change after the PCI to PCI-X backplane upgrade. For details on the new paths
for each slot, see the respective hardware upgrade manuals available at http://docs.hp.com.
For vPars and other changes, including the correct LVM and VxVM modifications on a vPars system, please
see the LVM and vPars IO Backplane Upgrade document at:
http://docs.hp.com/hpux/11i/index.html#Virtual%20Partitions
Please be aware that instead of performing the upgrades for LVM, vPars, etc., you also have the option of
performing a cold-install on the upgraded rp8420 or rp7420 as if they were new systems with no previous
installations.