HP-UX Virtual Partitions Release Notes (A.03.02)

vPars Release Notes
Known Problems and Workarounds
Chapter 1 5
TC command of the GSP
JAG
JAGae41558
Description
Initiating a TC (Transfer of Control) at the GSP (Guardian Service
Processor) while the vPars monitor is booted may cause the hard
partition/system to hang.
Symptoms
If the vPars monitor is booted (in other words, there is a MON> prompt at
the console), and if a TC is issued via the GSP, the hard partition/system
may hang.
Workaround
If the hard partition or system hangs, issue a RS (hard reset) at the GSP of
the hard partition/system.
Configuring an Ultra2 or Ultra160 Card with the vparutil command
JAG
JAGaf00411
Description
On the nPartition-able servers (rp8400, rp8420, rp7420, rp7410, rp7405,
and Superdome), using the vparutil command to configure an Ultra2 or
Ultra160 SCSI card can cause the virtual partition that owns the SCSI card
to fail to boot.
Symptoms
On the nPartition-able servers, the virtual partition connected to an Ultra2
or Ultra160 SCSI boot device fails to boot after the SCSI card was
configured using the vparutil command.